HXC series is a low cost distance monitor USD 59 in hundreds. It
uses a wide beam transceiver, and is therefore less sensitive to the
orientation of the object. It is useful for position or level
measurements in cases where the objects are not necessarily flat and
orderly. And it may also be useful for liquid level measurement. The table below is a
general selection guide, if you don't find a device that suits your
application, let us know we can change the parameters.
|
ABSOLUTE MAXIMUM RATINGS |
| Ambient temperature during operation |
-40°C to +125°C |
| Storage temperature |
-65°C to +150°C |
| Voltage on the
Brown wire |
-0.3V to (Vsupply + 0.3V) |
| Voltage on the
Red wire with respect to the black wire |
-0.3V to +5.5V |
| Maximum current
out of Black Wire |
300 mA |
| Maximum current
into the Red Wire |
250 mA |
|
Wire Configuration |
| Wire Color |
Function |
| Red* |
Vsupply in 3 to 5.5 V |
| Brown |
Variable voltage (max drive capacity 5mA) |
| Black |
Gnd (return) |
* WARNING if you reverse polarize the device
or violate the absolute maximum ratings the device can be damaged.
The illustration below shows how the HXC converter
series can be applied. The brown wire is connected to a volt meter.

In case of the Distance to Voltage converters the voltage
is proportional to the distance or
- Voltage (brown wire) = (Vsupply * D)/(Max Distance)
In case of the Proximity to Voltage converters the
relationship is as follows
Voltage (brown wire) = Vsupply * (Max Distance - D) / (Max
Distance)
Where D is the distance between the reflecting surface and
the converter. Max Distance is as specified in the Distance to Voltage
converters, or Proximity to Voltage tables below
|
DISTANCE TO VOLTAGE CONVERTERS more
information |
| Part No. |
Min Distance |
Max Distance |
Response |
Typical Precision |
Vsupply Volts |
Current mA* |
output Volt level |
| HXC101D100 |
0.1m |
1m |
1000mS |
0.6 mm |
3 - 5.5 |
20 - 40 |
0 to Vsupply |
| HXC101D5 |
0.1m |
1m |
20mS |
8 mm |
3 - 5.5 |
20 - 40 |
0 to Vsupply |
| HXC101D50 |
0.1m |
1m |
500mS |
2 mm |
3 - 5.5 |
20 - 40 |
0 to Vsupply |
* Power consumption is measured with the brown wire open (not
connected)
|
PROXIMITY TO VOLTAGE CONVERTERS |
| Part No. |
Min Distance |
Max Distance |
Response |
Typical Precision |
Vsupply Volts |
Current mA* |
output Volt level |
| HXC101P100 |
0.1m |
1m |
1000mS |
0.6 mm |
3 - 5.5 |
20 - 40 |
0 to Vsupply |
| HXC101P5 |
0.1m |
1m |
20mS |
8 mm |
3 - 5.5 |
20 - 40 |
0 to Vsupply |
| HXC101P50 |
0.1m |
1m |
500mS |
2 mm |
3 - 5.5 |
20 - 40 |
0 to Vsupply |
* Power consumption is measured with the brown wire open (not
connected)

Beam Pattern
The sensor is located in the locus of the polar plot
shown below facing north, maximum signal strength is along the 0 degree
axis. As the observer with the measuring instruments moves east and west
i.e. perpendicular to the 0 line signal strength degrades. The beam
pattern character line shown below represents observation angles where
signal has degraded by 6 decibels.