The HE66X Block Diagram

The illustration on the right shows the internal block structure of the HE66X units. The signal from the sensor is conditioned using an amplifier and a second order band pass filter. The output driver is a push pull type utilizing passive boost. Data is coupled via RS485 conditioner to the network.

Important: The HE66X is extremely sensitive, while connected to a computer ungrounded switcher power supplies from laptops and desktop can disturb the HE66X. In case of trouble make sure any device connected to the HE66X is well grounded. Laptops, palmtops or devices running on batteries do not disturb the unit while connected.
The communication parameters for the HE66XP485 version are 
19200 baud, 8 bit, 1 stop bit, no parity. No Xon/Xoff handshaking

HE660 Enclosures PVC, IP68 compliant. Shape cylindrical Size 0.8" dia, 6" long

Wire color configuration for the HE660

Sensor wires cable color gray 2 conductors and a shield

RED

Sonar out: transmits sonar signal max 60Vp-p

YELLOW

Sonar in: receives sonar signal

SHIELD

Signal return (Ground)

When connecting a transceiver (single element for both transmission and reception) Red and Yellow can be connected together.

Control wires cable color black: 6 conductors

Wire HE660P232 HE660P485

RED

Power 7 to 16Vdc

Power 7 to 16Vdc

GREEN

Return (Ground)

Return (Ground)

BLACK

Serial Receive (input)

RS485 -

YELLOW

Serial Transmit (output)

RS485 +

WHITE

PWM / Alarm Output

PWM / Alarm Output

BLUE

Auxiliary Power

Auxiliary Power

 

Electrical Specification

Parameter

Value

Units

Power

7 - 16 

Volts

Current consumption

10

mA

Output Power Excitation (Push Pull)

300

mW

PWM output (source) 10 mA
PWM output (sink) 20 mA
PWM cycle time 64 lS